MESA+ University of Twente
The BIOS Lab-on-a-chip group

Publications

Theses

Bohm, Dr.ing. S. (2000, June 23). The comprehensive integration of microdialysis membranes and silicon sensors. Universiteit Twente, 176 pp. Promotor(en): Prof.dr.ir. P. Bergveld. Assistent promotor(en): Dr.ir. W. Olthuis. ISBN 90-365-1462-2.

Scientific publications

Bergveld, P.(2000). Bedside clinical chemistry: from catheter tip sensor chips towards micro total analysis systems. Biomedical microdevices, 2 (nr: 3), (pp. 185-195). ISSN 1387-2176.

Bohm, S., Olthuis, W., & Bergveld, P.(2000). A generic design of a flow-through potentiometric sensor array. Mikrochimica acta (1966), (nr: 134), (pp. 237-243). ISSN 0026-3672.

Bohm, S., Olthuis, W., & Bergveld, P.(2000). A micromachined double lumen microdialysis probe connector with incorporated sensor for on-line sampling. Sensors and actuators B (Chemical), 2000 (nr: B63), (pp. 201-208). ISSN 0925-4005.

Bohm, S., Burger, G.J., Korthorst, M.T., & Roseboom, F.(2000). A micromachined silicon valve driven by a miniature bi-stable electro-magnetic actuator. Sensors and actuators A (Physical), 2000 (nr: 80), (pp. 77-83). ISSN 0924-4247.

Hietanen, J., Bomer, J.G., Jonsmann, J., Olthuis, W., Bergveld, P., & Kaski, K.(2000). Damping of a vibrating beam. Sensors and actuators A (Physical), (nr: 86), (pp. 39-44). ISSN 0924-4247.

Langereis, G.R., Olthuis, W., & Bergveld, P.(2000). A demonstration of acquiring specific concentration data by variations in the operating conditions of a non-specific sensor. Chemometrics and intelligent laboratory systems, 2000 (nr: 50), (pp. 211-223). ISSN 0169-7439.

Olthuis, W., Kooi, B.J., Bomer, J.G., & Bergveld, P.(2000). Load to capacitance transfer using different spring elements in capacitive transducers. Sensors and actuators A (Physical), 2000 (nr: 85), (pp. 256-261). ISSN 0924-4247.

Schasfoort, R.B.M., Schlautmann, S., Hendrikse, J., & Berg, A. van den.(2000). Field-effect flow control for microfabricated fluidic networks. Science, 1999 (nr: 286), (pp. 942-945). ISSN 0036-8075.

Dam Thi Van Anh, D.T.V.A., Olthuis, W., & Bergveld, P.(2000, December 01). Electrochemical deposition of potassium ferric ferrocyanide for chemical sensors., [SeSens 2000 (CD-rom)].(pp. 605-607). Veldhoven. ISBN 90-73461-24-3.

Books

Berg, A. van den. (editor), Olthuis, W. (editor), & Bergveld, P. (editor)(2000). Micro Total Analysis Systems 2000. Dordrecht: Kluwer Academic Publishers 623 pp. ISBN 0-7923-6387-6.

Book chapters

Olthuis, W., Bohm, S., Langereis, G.R., & Bergveld, P.(2000). Selection in system and snesor. Chemical and Biological Sensors for Environmental Monitoring (pp. 60-85). Washington, DC, USA: American Chemical Society. ISBN 0-8412-3687-9.

Conference papers

Albers, H., & Bergveld, P.(2000, July 02). A planar cartridge system for measuring the dynamic response of a poly-lysine covered ISFET on a stimulus for measuring heparine., [8th International Meeting on Chemical Sensors].(pp. 152-152). Basel, Switzerland.

Bohm, S., Olthuis, W., & Bergveld, P.(2000, January 23). A bi-directional electrochemically driven micro liquid dosing system with integrated sensor/actuator electrodes., [Proc. The Thirteenth Annual International Conference on Micro Electro Mechanical Systems 2000].(pp. 92-95). Miyazaki, Japan. ISBN 0-7803-5273-4.

Bohm, S., Timmer, B., Olthuis, W., & Bergveld, P.(2000, May 14). A closed loop controlled electrochemically actuated micro dosing system for in situ sensor calibration., [Micro Total Analysis Systems 2000].(pp. 347-350). Enschede. ISBN 0-7923-6387-6.

Bohm, S., Linden, H. van der., & Berg, A. van den.(2000, May 14). High pressure gas-liquid mixtures generated in a micro-electrolysis cell., [Micro Total Analysis Systems 2000].(pp. 611-614). Enschede. ISBN 0-7923-6387-6.

Linden, H.J. van der., Olthuis, W., & Bergveld, P.(2000, May 14). Finding a good hydrogel composition for hydrogel based microvalves., [Micro Total Analysis Systems 2000].(pp. 175-178). Enschede. ISBN 0-7923-6387-6.

Schasfoort, R.B.M., Guijt-Van Duijn, R., Schlautmann, S., Frank, H., Billiet, H.A.H., Dedem, G.W.K. van., & Berg, A. van den.(2000, May 14). Miniaturized capillary electrophoresis system with integrated conductivity detector., [Micro Total Analysis Systems 2000].(pp. 391-394). Enschede. ISBN 0-7923-6387-6.

Sprenkels, A.J., Olthuis, W., & Bergveld, P.(2000, October 12). On the integration of a microdialysis-based microTAS with calibration facility on a silicon-glass sandwich., [1st Ann. Int. IEEE-EMBS Special Topic Conf. on Microtechnologies in Med. & Biol.].(pp. 326-330). Lyon, France. ISBN 0-7803-6603-4.

M.Sc.-reports

Timmer, B.H. (2000, april 18). A push/pull micro dosing system for fluid handling in m TAS applications. Universiteit Twente, Report BIOS00-2R, Enschede.

Other publications

Dam Thi Van Anh, D.T.V.A., Albers, H., Bohm, S., Olthuis, W., & Bergveld, P.(2000, March 29). A flow through potentiometric micro sensor based on dialysis tubing., [Poster Workshop Sensortechnologie 2000]., Woudschoten.

Dam Thi Van Anh, D.T.V.A., Albers, H., Bohm, S., Olthuis, W., & Bergveld, P.(2000, March 29). A potentiometric sensor based on the E-MOSFET., [Poster Workshop Sensortechnologie 2000]., Woudschoten.

Dam Thi Van Anh, D.T.V.A., Albers, H., Bohm, S., Olthuis, W., & Bergveld, P.(2000, March 29). Sensor chipcard system - using the dynamic response of the ISFET on a steplike change in the ion-strength., [Poster Workshop Sensortechnologie 2000]., Woudschoten.

Dam Thi Van Anh, D.T.V.A., Olthuis, W., & Bergveld, P.(2000, March 29). The EMOSFET a transducer for redox measurements., [Poster Workshop Sensortechnologie 2000]., Woudschoten.

Patents

Bergveld, P. (aanvraag: 2000, August 31). Microdialysis-probe integrated with Si-chip. Octrooi. US - PCT/NL99/00057 2000-531738- WO 99/41606 -PCT/NL99/00057.