MESA+ University of Twente
The BIOS Lab-on-a-chip group

Publications

Theses

Lotters, Ir. J.C. (1997, August 28). A highly symmetrical capacitive traxial accelerometer. Universiteit Twente, 194 pp. Promotor(en): Prof.dr.ir. P. Bergveld. Assistent promotor(en): Dr.ir. W. Olthuis. Prof.dr.ir. P.H. Veltink. ISBN 90-365-0982-3.

Pedersen, Ir. M. (1997, August 22). A polymer condenser micorphone realised on silicon containing preprocessed integrated circuits. Universiteit Twente, 200 pp. Promotor(en): Prof.dr.ir. P. Bergveld. Assistent promotor(en): Dr.ir. W. Olthuis. ISBN 90-365-0994-7.

Schellin, R. (1997, May 23). Integrierte piezosensitive und Kapazitive Ein-Chip-Silizium-Mikrofone. Technische Hochschule Darmstadt, Fachbereich Elektrotechnike und Informationstechnik, 196 pp. Promotor(en): Prof.dr. G.M. Sessler. Assistent promotor(en): Prof.dr. W. Langheinrich. Prof.dr.ir. P. Bergveld.

Scientific publications

Bergveld, P., Eijkel, J.C.T., & Olthuis, W.(1997). Detection of protein concentrations with chronopotentiometry. Biosensors and bioelectronics, 12 (nr: 9-10), (pp. 905-916). ISSN 0956-5663.

Eijkel, J.C.T., Olthuis, W., & Bergveld, P.(1997). An ISFET-based dipstick device for protein detection using the ion-step method. Biosensors and bioelectronics, 12 (nr: 9-10), (pp. 991-1002). ISSN 0956-5663.

Eijkel, J.C.T., Bosch, C.J., Olthuis, W., & Bergveld, P.(1997). Constructing a proton titration curve from ion-step measurements, applied to a membrane with adsorbed protein. Journal of colloid and interface science, 187 (pp. 148-158). ISSN 0021-9797.

Eijkel, J.C.T., Olthuis, W., Kolev, S.D., & Bergveld, P.(1997). Measuring donnan-related phenomena using a solid-state ion sensor and a concentration-step method. Journal of membrane science, 127 (pp. 203-221). ISSN 0376-7388.

Kruise, J., Eijkel, J.C.T., & Bergveld, P.(1997). Detection of protein concentrations using a pH-step titration method. Sensors and actuators B (Chemical), 1997 (nr: 44), (pp. 297-303). ISSN 0925-4005.

Lotters, J.C., Olthuis, W., Veltink, P.H., & Bergveld, P.(1997). Design, realization and characterization of a symmetrical triaxial capacitive accelerometer for medical applications. Sensors and actuators A (Physical), A61 (pp. 303-308). ISSN 0924-4247.

Lotters, J.C., Olthuis, W., Veltink, P.H., & Bergveld, P.(1997). Polydimethylsiloxane, a photocurable rubberelastic polymer used as spring material in micromechanical sensors. Microsystem technologies, 3 (nr: 2), (pp. 64-67). ISSN 0946-7076.

Lotters, J.C., Olthuis, W., Veltink, P.H., & Bergveld, P.(1997). The mechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applications. Journal of micromechanics and microengineering, 7 (pp. 145-147). ISSN 0960-1317.

Olthuis, W., Sprenkels, A.J., Bomer, J.G., & Bergveld, P.(1997). Planar interdigitated electrolyte-conductivity sensors on an insulating substrate covered with Ta2O5. Sensors and actuators B (Chemical), 1997 (nr: 43), (pp. 211-216). ISSN 0925-4005.

Pedersen, M., Meijerink, M.G.H., Olthuis, W., & Bergveld, P.(1997). A capacitive differential pressure sensor with polyimide diaphragm. Journal of micromechanics and microengineering, 7 (pp. 250-252). ISSN 0960-1317.

Pedersen, M., Olthuis, W., & Bergveld, P.(1997). A silicon condenser microphone with polyimide diaphragm and backplate. Sensors and actuators A (Physical), A63 (pp. 97-104). ISSN 0924-4247.

Pedersen, M., Meijerink, M.G.H., Olthuis, W., & Bergveld, P.(1997). An IC-compatible polyimide pressure sensor with capacitive readout. Sensors and actuators A (Physical), A63 (nr: 3), (pp. 163-168). ISSN 0924-4247.

Pedersen, M., Schellin, R., Olthuis, W., & Bergveld, P.(1997). Electro-acoustical measurements of silicon microphones on wafer scale. Journal of the Acoustical Society of America, 101 (pp. 2122-2128). ISSN 0001-4966.

Pedersen, M., Olthuis, W., & Bergveld, P.(1997). Harmonic distortion in silicon condenser microphones. Journal of the Acoustical Society of America, (pp. 1582-1587). ISSN 0001-4966.

Volanschi, A., Nijman, J.G.H., Olthuis, W., & Bergveld, P.(1997). Microcavity electrodes used as single-nucleation site electrodes for the electrolysis of water. Sensors and materials, 9 (nr: 4), (pp. 223-240). ISSN 0914-4935.

Conference papers

Bergveld, P., Olthuis, W., & Kruise, J.(1997, September 21). The application of ISFETs to determine the acid-base behaviour of proteins., [Eurosensors XI].(pp. 1153-1156). Warsaw, Poland. ISBN 83-908335-0-6.

Bohm, S., Bonaccurso, E., Olthuis, W., & Bergveld, P.(1997, September 21). The control of pH in a flowing liquid by coulometric actuation., [Proceedings of Eurosensors XI].(pp. 1161-1164). Warsaw, Poland. ISBN 83-908335-0-6.

Hendrikse, J., Olthuis, W., & Bergveld, P.(1997, June 19). A drift free nernstian iridium oxide PH sensor., [Transducers '97].(pp. 1367-1370). Chicago, USA. ISBN 0-7803-3829-4.

Hendrikse, J., Olthuis, W., & Bergveld, P.(1997, September 21). A novel potentiometric oxygen sensor based on the EMOSFET., [Proceedings of the 11th European Conference on Solid-State Transducers].(pp. 35-38). Warsaw, Poland. ISBN 83-908335-0-6.

Langereis, G.R., Olthuis, W., & Bergveld, P.(1997, June 17). Measuring conductivity, temperature and hydrogen peroxide concentration using a single sensor structure., [Transducers '97].(pp. 543-546). Chicago, USA. ISBN 0-7803-3829-4.

Lotters, J.C., Olthuis, W., Veltink, P.H., & Bergveld, P.(1997, June 19). Characterisation of a highly symmetrical miniature capacitive triaxial accelerometer., [Transducers '97].(pp. 1177-1180). Chicago, USA. ISBN 0-7803-3829-4.

Lotters, J.C., Olthuis, W., Veltink, P.H., & Bergveld, P.(1997, January 26). Theory, technology and assembly of a highly symmetrical capacitive triaxial accelerometer., [MEMS '97].(pp. 31-36). Nagoya, Japan. ISBN 0780337441.

Olthuis, W., Volanschi, A., & Bergveld, P.(1997, June 18). Dynamic surface tension measured with an integrated sensor-actuator device using electrolytically generated gas bubbles., [Transducers '97].(pp. 1059-1062). Chicago, USA. ISBN 0-7803-3829-4.

Pedersen, M., Olthuis, W., & Bergveld, P.(1997, June 17). A polymer condenser microphone on silicon with on-chip cmos amplifier., [Transducers '97, vol 1].(pp. 445-446). Chicago, USA. ISBN 0-7803-3829-4.

Pedersen, M., Olthuis, W., & Bergveld, P.(1997). Fabrication of IC-compatible capacitive sensors by polymer processing., [Proceedings of the SPIE Conference on Smart Structures and Materials].(pp. 70-81). San Diego, USA. ISBN 0-8194-2459-5.

Schipper, J., Lotters, J.C., Veltink, P.H., Olthuis, W., & Bergveld, P.(1997, September 21). Procedure for in-use calibration of triaxial accelerometers., [Proceedings of Eurosensors XI].(pp. 1599-1602). Warsaw, Poland. ISBN 83-908335-0-6.

M.Sc.-reports

Kooi, B.J.(1997, August 25). Improvement of the reproducibility of a highly summetrical capacitive triaxial accelerometer. Enschede.

Schipper, J.(1997, January 30). The design and realisation of a calibration procedure for in use calibration of the triaxial accelerometer. Enschede.

Wehrmeijer, M.(1997, December 01). Transducer optimization for ultrasonic distance detection. Universiteit Twente-EL, Enschede.

Patents

Saaman, A. Sprenkels, A.J. & Lintel, H.T.G. van. (verlening: 1997, December 03). Sealed joint between components for example of piezo-electrically controlled micro-pump - has silicium connector between glass and gold-plated surfaces, which are heated to produce seal. Octrooi. Nederland / EP809770A1.