R. Kroeske

Overview equipment

Equipment list MolMat

Make sure you have always received instruction before using equipment!

This equipment reservation calendar can be used after subscribtion. 
Obliged subscribtion for all our instruments (even if used for 10 minutes).

IN THE TABLE BELOW YOU WILL FIND THE EQUIPMENT THAT IS CURRENTLY OUT OF ORDER OR WHERE MAINTENANCE IS PLANNED

ITEM

DOWN / MAINTANANCE

EXPECTED DURATION

CONTACT 














  • AFM

    AFM

    LA 1730
    Responsibility of Hubert Gojzewski

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

  • CENTRIFUGES

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    HIGH SPEED CENTRIFUGE

    • (only for water based solutions)
    • Thermo Multifuge XR3
    • CR 4.238
    • Responsibility of Robin Meeuwisse

    ULTRACENTRIFUGE

    • Sorvall WX-80 ultra series
    • C4052
    • Responsibility of Robin Meeuwisse 
  • RAMAN IMAGING SETUP

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Raman imaging setup

    NT-MDT, NTegra Spectra
    CR 0.028(Laserlab)

    CSLM: Raman 
    AFM: Contact mode / Tapping mode / Force distance / Liquid AFM

    Responsibility of Dodo Wasserberg

  • CONTACTANGLE

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    CONTACTANGLE

  • ELECTROCHEMISTRY SETUP

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    ELECTROCHEMISTRY SETUP

    Autolab PGSTAT302N
    CR 4.516

    Responsibility of Niels van der Velde

  • FLASH CHROMATOGRAPHY

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.


    FLASH CHROMATOGRAPHY - BIOTAGE SELEKT

    • CR 4228
    • Responsibility of Richard Egberink
  • FLUORESCENCE SPECTROMETER

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    FLUORESCENCE SPECTROMETER

    Perkin Elmer
    CR 4.056

    Responsibility of Richard Egberink
    R.J.M.Egberink@utwente.nl

  • FPLC

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Fast protein liquid chromatography (FPLC)

    • Biorad NGC
    • CR 4.052
    • Responsibility of Robin Meeuwisse 
  • FTIR

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Fourier-transform infrared spectroscopy (FTIR)

    BrukerVertex 70V

    FOURIER-TRANSFORM INFRARED SPECTROSCOPY (FTIR)

    Bruker Alpha

  • GC

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Gas chromatography (GC)

    • Agilent 6850
    • C4052
    • Responsibility of Richard Egberink and Marcel de Bruine
  • HPLC

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    High-performance liquid chromatography (HPLC)

    Waters 

    • CR 4.052
    • Responsibility of: Richard Egberink

    Liquid chromatography–mass spectrometry (LC–MS) 

    Waters 

    • CR 4.052
    • Responsibility of: Richard Egberink
  • LIGHT SCATTERING

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Lightscattering

  • LYOPHILIZER

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    LYOPHILIZER

    Freeze Drying
    CR 4.052

    Responsibility of Marcel de Bruine and Ramon ten Elshof

  • MICROCALORIMETER

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    MICROCALORIMETER

    Microcal Peaq ITC
    CR 4.056

    Giulia Allegri

  • MICROSCOPES

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Olympus BH2 (c4052)

    OLYMPUS IX71 (C4309)

    OLYMPUS IX81 - FLUORESCENSE MICROSCOPE MOTORIZED STAGE (C4309)

    OLYMPUS BX61 (C4309)

    OLYMPUS IX71 - FLUORESENCE MICROSCOPES (C4250) 

    OLYMPUS BX60 (C4250)

    Responsibility of Marcel de Bruine / Clemens Padberg / Richard Egberink

  • MICROWAVE SYNTHESIZER

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Microwave Synthesizer

    Biotage Initiator
    CR 4.052

    Responsibility of Marcel de Bruine  

  • MILLI-Q ULTRA PURE WATER

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    MILLI-Q ULTRA PURE WATER

    Millipore
    CR 4.317

    Responsibility of Marcel de Bruine
    M.A.J.debruine@utwente.nl

  • ML-1: BACTERIOLOGIC LAB

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    ML-1: BACTERIOLOGIC LAB

    CR 4.318
    Safety Instruction: Pascal Jonkheijm P.Jonkheijm@utwente.nl

    Click here to watch the instruction movie

  • ML-1: CELL CULTURE LAB

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    ML-1: CELL CULTURE LAB

    CR 4.318
    Safety Instruction/General instruction: Pascal Jonkheijm

    Click here to watch the instruction movie

  • MS

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    COMPACT MASS SPECTROMETER

    • Advion Expression CMS + Plate Express
    • CR 4.056
    • Responsibility of Richard Egberink
  • NANODROP

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    NANODROP-ONE

    • Thermo
    • CR 4.056
    • Responsibility of Robin Meeuwisse
  • NANOIMPRINT

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Press for Nanoimprint lithography (NIL) 

    Specac HP

  • NMR

    Nuclear magnetic resonance (NMR) 

    C4315 - Bruker 400MHz (Robot)
    C4060 - Bruker 600MHz

    Responsibility of Ricardo Martinho
    r.pintoenesmartinho@utwente.nl 

  • OXYGEN PLASMA

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    OXYGEN PLASMA MACHINE (ONLY FOR SILICON)

    SPI plasmaprep II

    • C4244
    • Responsibility of Clemens Padberg 


    OXYGEN PLASMA MACHINE FOR PDMS LAYERS

    SPI plasmaprep II

    For more information about plasma cleaning:
    http://www.unisa.edu.au/iwri/staffpages/Siow%20et%20al%20PPP%20review.pdf

    SPI PLASMA-PREP™ II PLASMA ETCHER, CLEANER AND ASHER

    ETCH-CLEAN-ASH USING DRY PLASMA CHEMISTRY WITH BARREL-REACTOR ISOTROPIC ETCHING IN A PLASMA ETCHER.

    SPI Plasma-Prep II, a compact, "bench-top" sized plasma etcher, which can also serve as a plasma asher or even a plasma cleaner, uses dry plasma chemistry to reveal hidden detail for SEM and TEM analysis. This room-temperature plasma etching process works selectively, gently - and is well-suited for many applications in the EM lab, including work in: life sciences, materials science, electronics, AEM, failure analysis and general electron microscopy, including asbestos sample preparation*. Additionally, it is also widely used for the cleaning before use of microscope slides, both glass and quartz, and it is also used for the cleaning of transmission cells for a variety of different types of spectroscopic instrumentation

    For more information:
    http://www.2spi.com/catalog/instruments/etchers1.php

  • PEPTIDE SYNTHESIS

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    PEPTIDE SYNTHESIZER

    • Biotage
    • Resposibily of Gülistan Kocer
  • PIRANHA CLEANING

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    PIRANHA CLEANING

    CR 4.052

    Responsibility of Richard Egberink / Marcel de Bruine

  • POTENSIOSTAT / GALVANOSTAT

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Potentiostat Galvanostat 

    Metrohm PGstat 302N

  • RHEOMETER

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Rheometer

    Anton PaarUDS200

    • C4244
    • Responsibility of Mark Hempenius
  • SILANE NITROGEN BOX

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    SILANE NITROGEN BOX

    CR 4.052

    Responsibility of Marcel de Bruine

  • SEM

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    scanning electron microscope (SEM)  

    Jeol7610-Plus

  • SPINCOATER

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    SPINCOATER

    Model WS-650MZ-23NPP

    CR 4.052

    Responsibility of Marcel de Bruine

  • SPS SOLVENT PURIFICATION SYSTEM

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    SPS SOLVENT PURIFICATION SYSTEM

    M-Braun
    CR 4.317

    Responsibility of Marcel de Bruine
    M.A.J.debruine@utwente.nl

  • SPUTTERCOATER

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Sputtercoater

    JeolJFC-1300

  • TGA

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Thermogravimetric analysis

    TAInstrumentsTGA550

  • ULTRASONIC SONIFIER / SONICATOR

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    UltrasonicSonifier

    Branson SFX550 with different tips

    • C4244
    • Responsibilityof Timo Rheinberger
    • t.rheinberger@utwente.nl

    Fisherbrand™ Q700 Sonicator with Probe

    • C4052
    • Responsibility of Marcel de Bruine
  • UV-LAMP

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    UV-LAMP

    Honle BluePoint 2 Easy cure
    CR 4.238

    Responsibility of Marcel de Bruine
    M.A.J.debruine@utwente.nl

  • UV-VIS SPECTROSCOPY

    This device is only accessible to employees of the MolMat-cluster. Other groups can contact one of the technicians of the MolMat cluster to request access.

    Ultraviolet–visible spectroscopy (uv-vis)

    Perkin Elmer Lambda 850


    Jasco V-630

  • PLATE READER

    plate reader 

    Tecan infinite m nano

    • C4056
    • Responsibility of Marcel de Bruine
  • MALDI

    MALDI

    bRUKER SMARTFLEX

    • C4056
    • Responsibility of Ramon ten Elshof